Feature by Andrew Levido
Motor Control
Part 3: Stepping/Stepper Motors
This month, our topic is stepping (or stepper) motors. Unlike the DC & synchronous
motors we covered in the last few articles, the stepping motor rotates in a series
of discrete steps rather than continuously. This makes it very useful for applications
that require fairly precise position control without the need for feedback.
T
hese types of motors are found in many
low-cost positioning devices like 3D
or 2D printers, where the expense
of full-feedback servomotors is not
justified.
All the motors we have looked at so
far produce torque through the BIl relationship between flux density, current
and winding length. Stepper motors
are no different, although the mechanism is a bit more obscure.
Stepping motors generate torque
through a mechanism called variable
reluctance. You may recall that reluctance is the ‘resistance’ of a magnetic
circuit to magnetic flux.
The current in an electrical circuit tends to take the path of least
resistance because this is the lowest
energy state – it takes more voltage,
and therefore energy, to push a given
current through a higher resistance
than a lower one.
It is the same for magnetic flux –
it takes more magnetomotive force
(mmf), and thus more energy, to push
a flux through a higher reluctance path
than a lower one. Thus, flux tends to
seek the low-reluctance path.
Variable reluctance
This phenomenon can create a
torque in a variable reluctance motor,
like a stepping motor, through the
mechanism illustrated in Fig.1. In
this simplified example, a salient pole
stator carries three pairs of windings,
each set 120° apart. Opposite windings are wired such that their magnetic fields are orientated in the same
direction.
I have shown the top and bottom
poles energised in the direction that
makes the magnetic field point upward
through the rotor. The flux completes
its loop through the stator body, but I
have not bothered to show this to keep
the diagram uncluttered.
The rotor is made of laminated
transformer steel and also has salient
poles, but it has no windings – the
‘doubly salient’ characteristic is critical for torque production these motors.
If the rotor poles are fully aligned
Fig.1: stepping motors produce torque using variable reluctance. The torque
tends to push the rotor back into alignment with the stator, where the reluctance
is lowest.
50
Silicon Chip
Australia's electronics magazine
with the stator poles, as shown on the
left, the low-reluctance path ensures
the magnetic flux produced by the
stator is evenly distributed across the
poles and the flux densities on the
winding on the top left in which current comes out of the page and the
one on the top right where it goes in
are equal.
There are still BIl forces on each of
the energised windings (blue arrows),
but they are equal and opposite, so
they cancel out and the net reactive
torque on the rotor is zero.
If the rotor is turned by a slight angle,
as shown in the diagram on the right,
the area of the air gap between the
rotor and stator saliencies decreases.
The field lines bunch together because
they still want to take the lowest reluctance path, so the flux density in this
region increases.
The flux is no longer evenly distributed across the energised stator poles.
At the right-hand side of the top stator, the flux density is higher, so the
winding on the right sees a higher BIl
force than the one on the left. The same
thing happens on the other side at the
bottom pole.
The BIl forces on the windings are
therefore unbalanced, indicated by the
length of the blue vectors, resulting in a
net torque on the rotor in the direction
that tries to pull it back into alignment
with the stator. The opposite would
happen if we turned the rotor counterclockwise; the rotor always wants to
pull back to the neutral position where
the reluctance is minimum.
The same thing would happen if the
current in the windings were reversed.
The magnetic field through the rotor
would point down, but the net force
will always act to pull the stator back
siliconchip.com.au
Fig.2: when the current commutates from the U-phase to the V-phase, the rotor shifts by 30° to align with the V-phase pole
pair. Different pole configurations produce different step angles.
to the minimum reluctance, fully
aligned position.
If we now energise successive sets of
poles in sequence, as shown in Fig.2,
the rotor is pulled around so that the
nearest rotor poles align with the
newly energised stator poles. In this
motor with three stator pole pairs and
four rotor poles, the step angle is 30°.
The step angle (θ) is related to the
number of rotor poles (Pr) and the
number of stator pole pairs (Ns) by the
expression θ = 2π ÷ (Pr Ns) for radians and θ = 360 ÷ (Pr Ns) for degrees.
In the example in Fig.2, the phases
are energised in a U-V-W sequence
counter clockwise around the rotor,
and the stable rotor angle rotates clockwise. You can probably see that if the
phase sequence was U-W-V, the rotor
would move the other way.
A variable reluctance motor therefore rotates in a series of discrete angular steps each time the stator current
commutates from one winding to the
next. Between commutations, the rotor
is ‘locked’ at a stable angle and will
resist attempts to move it. This precise
rotor positioning and ‘holding torque’
is what makes these motors handy for
positioning applications.
Unfortunately, there is no neat
electrical model or simple equation
for torque vs angle or speed for these
motors because everything depends
on the magnetic design of the motor.
However, we can look at the general
shape of the torque-angle characteristic and see what we can learn from it.
Fig.3(a) shows three generalised
torque-angle curves, each in a different
colour according to which winding is
energised. Only one of these curves is
valid at any given time. The solid dots
represent the stable low-
reluctance
rotor angle where there is zero torque.
These dots will be 30° apart for the
motor in Fig.2, but could be at different angles for motors with different
stator and rotor pole configurations.
Imagine the blue phase is energised.
With no shaft load, the rotor is stable
at the angle indicated by the solid blue
dot. If some load torque is applied,
the rotor angle will move up or down
the curve to the point that the motor
and load torques are balanced. One
such point is indicated by the hollow
blue circle.
The angle of the rotor does change a
bit with applied torque, but the characteristic is fairly steep in real motors,
so the angle does not change a huge
amount.
If the current commutates from the
blue phase to the green phase, the
operating point shifts up to the green
curve along the vertical black line.
The torque initially increases significantly as the operating point rides up
the green curve, accelerating the rotor
toward the next pole.
Once the rotor angle passes the
green curve’s peak, the torque reduces
until the rotor angle reaches the next
stable angle indicated by the hollow
green circle. The rotor has skipped
ahead one step.
This will obviously only work if
the initial blue-phase operating point
is at or below the intersection of the
blue and green curves shown by the
horizontal dotted line. If the operating
point were above this ‘pull-out torque’
(Tpo), the green phase would not be
able to ‘catch’ the rotor and the step
would be missed.
Depending on the circumstances,
the rotor may or may not resynchronise, but if you are relying on the
stepper to arrive at a precise angle,
you will be out of luck. This ‘missed
step’ problem is probably the most
Fig.3: these charts together show the torque-speed and torque-angle characteristics of a typical stepping motor. There is no
simple equation or model to describe their behaviour. ω is proportional to the drive pulse frequency.
siliconchip.com.au
Australia's electronics magazine
December 2026 51
Fig.4: a hybrid stepping motor includes a permanent magnet in the rotor. This example has 50 rotor poles and four stator
pole-pairs for a step angle of 1.8°.
common difficulty people encounter
when using stepper motors for the
first time. It is made more difficult by
the fact that the pull-out torque is not
fixed for a given motor.
When the rotor transitions from
one stable position to another, it does
not do so linearly, or even in perfect
steps. The rotor and load’s moment
of inertia will take it a little past the
next equilibrium point where the net
torque will reverse, pulling it back. It
may take a few oscillations until the
rotor settles at its steady-state position,
as shown in Fig.3(b).
It takes a finite time to settle, and
the faster you move it, the more pronounced the overshoot will be. This
imposes some limitations on the stepping rate and therefore the rotor speed.
If you try to step too fast, the rotor does
not have time to ‘lock on’ to the stable
angle before it has to move to the next,
and a step may be missed, or synchronisation may be lost altogether.
The result of all this is that the pullout torque reduces as the step rate
increases, as shown in the blue curve
in Fig.3(c). Some version of this curve
is usually provided in the motor’s data
sheet. The horizontal axis is step rate,
sometimes called pulse frequency for
reasons we will get to in a moment,
or shaft speed (in RPM or radians per
second).
The pull-out torque drops off dramatically with step rate until it reaches
some maximum response frequency,
where even the unloaded rotor cannot keep up.
There is also a pull-in torque limit,
as shown by the red line on the graph,
although you will rarely find this mentioned in the data sheets. This is the
maximum load torque that the motor
can accelerate from stationary for a
given step rate.
It is not really relevant for most
applications, because you would normally ramp the step rate up from a low
value rather than banging it on full
bore on a stationary motor and load.
Hybrid stepping motor
That’s the theory out of the way. If
we want to get practical, we need to
Photo 1 (left): you
can clearly see the
offset between the
segments in this photo
of the rotor of a NEMA 17 sized 1.8°
stepper. This offset is critical for the
operation of hybrid stepper motors.
Photo 2 (right): this is the stator from
the same motor as above. The four
pole-pairs, each with six saliences,
are clearly visible.
52
Silicon Chip
Australia's electronics magazine
talk about hybrid stepping motors,
which are the types you will most
commonly encounter in the wild. The
ubiquitous “NEMA” type motors with
the square-ish body are hybrid types.
The most common variant has 200
steps per revolution (a 1.8° step angle)
and comes in a range of standardised
frame sizes.
The NEMA size designation is the
approximate width and height of the
motor frame in tenths of an inch. For
example, a NEMA 17 motor is roughly
1.7 inches (43mm) square. For more
on NEMA stepper motors, see our article titled “A quick primer on stepper
motors” (January 2019; siliconchip.au/
Article/11370).
To achieve a 1.8° step angle requires
lots of poles: 50 rotor poles and four
stator pole-pairs is a common combination. Such a large number of necessarily small rotor poles makes it difficult to get adequate flux density using
the stator windings alone. These stepper motors therefore have permanent
magnets in the rotors to provide some
additional flux – hence the “hybrid”
designation.
The elevation in Fig.4 shows a side
view of the rotor. The magnets are
positioned axially in the rotor, which
is divided into two sections. Each section has 50 poles, which look a bit like
the teeth of a gear. Critically, these sections are fixed to the rotor such that
the ‘teeth’ on one section are aligned
with the ‘slots’ on the other.
Photo 1 is a photo of a rotor and its
bearings from a NEMA 17 motor. The
rotor slots and the gap between the
rotor sections are filled with epoxy,
but you can clearly see the offset.
The rotor in this photo has two
siliconchip.com.au
sections. You can stack pairs of sections end-to-end on a common shaft
to achieve higher torque, but you need
a correspondingly longer stator. This
is why NEMA-style stepping motors
come in different lengths for each
frame size.
The stator of this motor (Photo 2) has
four pole pairs arranged in two phases.
Each pole has several saliences on the
same pitch as the rotor poles. You can
see how the stator and rotor interact if
you look at the cross-section diagram
in Fig.4. This cross-section is through
the stator and the north pole section of
the rotor. We will start by considering
what is going on when no windings
are energised.
The flux produced by the permanent magnet crosses the air-gap from
the north rotor section to the stator
poles, flows axially along the stator
and back across the air gap to the
south-pole rotor section. Crucially, the
offset between rotor sections ensures
the reluctance of the flux path through
each stator pole is about equal.
If the reluctance of each path were
not roughly equal, the permanent
magnet’s field would produce a strong
static torque that the torque produced
by the windings would have to overcome. If you have ever turned the shaft
of an unenergised hybrid stepping
motor, you know that you can do so
easily while feeling just a very light
‘detent’ torque.
We can understand how this works
by mentally following the flux path
through each stator pole-pair. In the
case of pole pair 1, the flux passes
from the north rotor segment through
the fully aligned poles on the north
end of the motor and back via the
fully unaligned pole pair to the south
rotor segment.
The same sequence happens for
pole-pair 3, except the unaligned segment is at the north end and the aligned
segment is at the south. The flux paths
through pole pairs 2 and 4 are through
two sets of half-aligned air gaps.
By sizing the teeth and slots just
right, the designers make the reluctance of all the paths almost identical. This clever design means the flux
produced by the permanent magnets is
available to assist the windings in creating torque when they are energised,
but does not produce much torque on
its own.
When the green winding is energised, the flux it produces adds to the
siliconchip.com.au
permanent magnet flux to create a
holding torque that locks the rotor in
the position shown in the cross-section
in Fig.4. When the current commutates
from the green winding to the blue
one, the rotor advances clockwise by
the 1.8° necessary to align pole-pair 2,
as shown in Detail A.
The directions shown are for positive current. If we had energised the
blue winding with a negative current, the rotor would have moved
1.8° anti-clockwise. To rotate clockwise, the phases would be energised
in the sequence +G, +B, –G, –B, and
to rotate anti-clockwise the sequence
is +G, –B, –G, +B.
In reality, we don’t usually energise
single windings in a hybrid stepper
motor unless we are microstepping
(more on that below), but it is easier
to understand the motor’s operation if
we make this simplification for now.
Driving stepper motors
The important thing to note is that
to use a permanent-magnet or hybrid
stepper motor, we have to be able to
drive current through the windings
in either direction. How we do this
depends on the configuration of the
motor windings.
A bipolar or 4-wire stepping motor
like that shown in Fig.5 has a single
pair of wires for each phase and therefore each requires full-bridge drivers so current can be pushed through
the windings in either direction. In
a unipolar or 6-wire stepping motor,
each winding is centre-tapped such
that current flowing from the common
wire to each end produces flux in the
opposite direction.
This means the power electronics
to drive 6-wire motors is simpler, but
it comes at the expense of reduced
torque for a given motor size, since at
any time only half of each winding is
carrying current.
You can operate a 6-wire motor as a
bipolar one by ignoring the common
terminal of each winding and driving
the ends of the winding with a fullbridge. That is why most off-the-shelf
stepper motor drivers use the fullbridge configuration.
Unlike most motors, the current
through a stepping motor is not
directly proportional to torque. These
motors, especially small ones, draw
about the same current whether stationary or moving, loaded or unloaded.
The only thing limiting the current
is the DC resistance of the windings,
so you almost always need to use a
current-mode controller to drive them.
These motors usually have both a
voltage rating and a current rating,
but it is the latter you really need to
pay attention to. You will burn out
the motor if you exceed this for any
length of time.
Stepping and microstepping
As mentioned above, we don’t usually drive a hybrid stepping motor
Fig.5: 4-wire or bipolar stepping
motors have one pair of terminals for
each phase and must be driven by
a full-bridge. Six-wire or ‘unipolar’
steppers have a centre-tapped
winding which simplifies the drive
requirements at the expense of lower
torque.
Australia's electronics magazine
December 2026 53
Fig.6: microstepping creates intermediate steps for increased angular resolution
and lower motor noise. The torque available at the incremental positions is
lower than that at the full-step angles, though.
using just one of the two phases. We
get maximum torque if we energise
both windings at the same time, which
shifts the stable rotor position halfway
between the stator poles. You can think
of this as adjacent pole pairs (say 1 &
2 in Fig.4) forming a single larger pole
if that helps.
You can see this in action in the simplified representation of a two-phase
stepper in Fig.6 (at upper left). This
motor has two rotor poles and two
stator pole-pairs, so nominally each
step is 90°. During each full step, the
red and blue phases windings are both
energised, and the stable rotor angles
fall between the stator poles.
Note that this is a stylised drawing
– a motor that actually looked like this
would not work!
In each stable full-step position,
both windings are energised with
100% of the nominal current, albeit
in different permutations of polarity,
54
Silicon Chip
and the torque is maximised. The
rotor will jump very positively from
angle to angle with a lot of overshoot
and ripple.
We have already seen that if we
energise a single winding, the rotor
aligns directly with that pole-pair.
We can use this to create intermediate
steps between each full step. This is
called half-stepping and is illustrated
at upper right in Fig.6. There are now
eight rotor positions instead of four,
and the step-angle is halved.
Still, there is a catch. In positions 2,
4, 6 & 8 where only one winding is energised, the holding torque is about half
that at the full-step angle. This lower
intermediate position torque is often
referred to as the “incremental torque”.
The advantage of half-stepping is
that the noise and vibration of the
motor are reduced, as is the magnitude of the angle overshoot each step.
You also get twice the angular resolution (so 0.9° in a 1.8° stepper) but half
the pull-out torque in the intermediate steps. There is no such thing as a
free lunch!
Because we (probably) have a
current-mode controller, we are not
limited to the three current levels we
have used so far (100% positive, zero
and 100% negative), so we could create more sub-steps by partially energising coils.
For example, we could create a stable position between steps 1 and 2 of
the half-step drive by partially energising the blue winding and fully energising the red winding. In this way, we
Australia's electronics magazine
could quadruple the number of steps
per revolution from four for full stepping to 16 for quarter stepping. The
first four steps of the 16-step sequence
are shown at lower left in Fig.6.
You can actually create any arbitrary
number of sub-steps, but powers of two
are the most common. Collectively,
these sub-stepping strategies are called
microstepping. Typical stepping motor
drivers capable of microstepping top
out at 32 sub-steps per full step. The
incremental torque is 1/8 of the full-step
torque, so this level of micro-stepping
is not all that useful for positioning
unless the load is very light.
The main use case for very small
micro-steps is to make the rotor movement smoother and quieter. This can
be useful since stepper motors tend to
operate at audio frequencies and they
can be loud. If you want proof, check
out the video clips online of people
using stepper motors to play music!
Getting practical
A good way to explore stepping
motors is to get hold of one and a lowcost driver module, then try them out.
The driver I bought (Photo 3) is a typical example. It is suitable for fourwire motors, can source and sink up
to 4.0A and operates from a 9-42V
DC supply. It is equipped with DIP
switches to select the motor current
and the step type.
It has opto-isolated logic inputs for
enable, direction and the step pulse. To
run the motor, you leave enable open,
so it is really a disable input.
siliconchip.com.au
Photo 3: a typical off-theshelf stepping motor
controller. This unit
is rated for 4.0A
and can be set
up for microstepping at
various
rates.
You can
also leave
the direction
input open if you only
need single-
direction rotation. The motor will take a single step
on every rising edge of the step input.
This direction/step pulse interface
is very common with stepper motor
drivers, and is the reason that a lot of
the stepping motor data sheets use the
term ‘pulse rate’ rather than step rate.
It is pretty easy to generate a suitable pulse train with a microcontroller using a timer, but you can use
more or less any source that can generate a 3.3V or 5V pulse train. I used
my signal generator with the output
amplitude and offset adjusted appropriately.
I hooked the driver up to a NEMA 17
350mA stepping motor. Scope 1 shows
the stator current waveforms at 500mA
per division for full-stepping at 100
pulses per second. The high-frequency
ripple on the current waveform is the
current-mode regulation in action.
I had the current limit set to 500mA
(the lowest setting), but with a 12V
supply, the motor current was roughly
350mA as expected. This was with no
load on the shaft, reinforcing the point
that variable-reluctance motor current
is not proportional to load as it is with
most other motor types.
Under these conditions, the shaft
was making very distinct steps and
was impossible to stall with my fingers.
Scope 2 shows the same waveforms for half-stepping mode. You
can clearly see the ‘shoulders’ on the
waveform where only one winding
is energised. The shaft rotation was
noticeably smoother, but I could make
the shaft skip intermediate steps with
my fingers.
Scope 3 is a close-up of the current waveform shape with 16× micro-
stepping enabled. The steps themselves are barely visible in the current
switching hash and the transitions
siliconchip.com.au
Scope 1: the
current waveforms
(500mA per
division) for a
NEMA 17 stepper
operating in
full-step mode
at 100 steps per
second. The hash
on the traces
is the currentmode controller
switching.
Scope 2: with
half-stepping, the
periods where
only one winding
is energised are
very apparent.
The torque
available during
these steps will
be half that at the
full-steps.
Scope 3: this
‘scope grab
shows the current
waveforms
with 16× microstepping. You can
barely make out
the steps. The
motor operation
was very quiet and
smooth, but the
impact on torque
was marked.
look more-or-less linear. The acoustic
noise made by the motor was much
lower with 16 micro-steps, but the very
low incremental torque between major
steps was very apparent, and it was
easy to stall the shaft with my fingers.
Conclusion
Stepping motors, particularly the
low-cost NEMA-style hybrid steppers,
are very useful tools if you are looking
for low-cost position control.
They are easy to drive using cheap
off-the-shelf modules or one of the
many stepping motor control chips
available from the usual suspects.
They play very nicely with microcontrollers, so they are a good choice for
many do-it-yourself projects.
Australia's electronics magazine
Their strengths are holding torque
and positioning, as long as you don’t
need to move too fast. They are not a
replacement for DC motors, whether
electrically or mechanically commutated, if you just need to turn a shaft.
They don’t run fast (even at moderate speeds they have terrible torque)
and they are not very efficient. If you
want it all – accurate positioning, high
speed and high torque, you probably
need a full-blown servomotor.
Nevertheless, if you can live with
the limitations I have mentioned (and
often you can), hybrid stepping motors
are a cost-effective option.
Next month we will take a look at
three-phase induction motors, focusSC
ing on field-orientated control.
December 2026 55
|