I decided to power the circuit from a
Current
Limiter
▶
▶
Design decisions
Inrush
▶
T
his Inrush Current Limiter is
designed to ‘soft start’ large power
amplifiers and power supplies,
although it would likely have application in other places, such as starting
modestly sized motors.
The principle is very simple: insert
a fixed resistance in series with the
mains input to the transformer for
the first second (or so) of operation,
then short it out with a power relay.
This allows the inrush current to be
reduced before the relay removes the
resistance from the circuit and allows
the full current required for operation.
We also provide an open-collector
output to act as a disable input for an
amplifier during power-on, minimising the current draw from the amplifier while the capacitor bank charges.
For switch-mode power supplies, it
is common to use a negative temperature coefficient (NTC) thermistor as
an inrush current limiter. These have
a resistance of a few tens of ohms initially, but as current flows through
them and they heat up, the resistance
drops to a fraction of the initial value,
to around 1W. The advantage of these
is simplicity – all you need to do is
insert the device in series.
However, for a serious power amplifier, we would need several of these in
parallel. Even so, we would need to
accept a voltage drop across them, and
at high currents, these devices run hot
– between 150°C and 200°C.
Furthermore, if you interrupt power
for a short time, they won’t have time
to cool down, and they don’t help with
that inrush current on the second and
subsequent switch-on events.
One way of avoiding the voltage
losses and dissipation of NTC thermistors used for inrush current limiting is
to put a relay across them and switch
it on after a delay, shorting the thermistor(s) out. That also has the benefit of
letting them cool down sooner.
However, once you’re doing that,
you have the option to use wire-wound
power resistors instead, bringing the
further advantage that their effectiveness no longer depends on temperature. So if you switch the unit off and
on rapidly, they will be just as effective each time, although they will get
hotter than they would from a single
switch-on event. So they need to have
a high power rating.
By Phil Prosser
While testing a
power supply with a 600VA toroidal
transformer and a substantial capacitor bank, I frequently
tripped the circuit breaker on my switchboard. This simple
circuit limits the inrush current for this type of power supply,
saving the hassle and making power-up much less eventful!
▶ Limits mains current draw to about 7A when an appliance is switched on
▶ Rapid detection of mains interruption, ensuring reliable soft starting
▶ The control circuitry is isolated from the mains
▶ Programmable 1-10s delay with a resistor (default is 1s)
▶ Open-collector output for disabling speakers or other loads while starting up
▶ Not affected by rapid on/off cycling
▶ Maximum load current: 8A
Australia's electronics magazine
December 2026 45
standalone transformer on the board. It
may seem extravagant to add an extra
transformer when we are likely limiting the inrush of a large transformer,
but we do not want to be subject to
the regulation of the large transformer.
If there is a heavy load on that transformer, there is the potential for its output to droop, and we don’t want that
affecting the operation of the Inrush
Current Limiter.
Furthermore, our onboard power
supply has been sized so that if the
mains input drops significantly below
220V AC, it will continue to operate
under both start up and mains fault
conditions; including brownouts.
Given that the source impedance of
a mains socket is not zero, the appliance will have a cord (possibly a long
one), and may even be plugged in via
an extension cord, when drawing tens
of hundreds of amps, it is not unlikely
for the voltage seen at the socket to
be substantially lower than nominal.
If the mains input is interrupted
briefly, an NTC inrush limiter will not
work. Our circuit detects a brief loss
of mains, switches the limiter in and
drives the open collector disable active.
This adds a couple of parts to the circuit
but it is an important feature.
This circuit has parts connected
directly to the Active mains conductor. To ensure maximum safety, the
transformer isolates all but the relay
and 10W resistors from the mains.
Because it’s floating, we can safely connect the ground of the Inrush Current
Limiter to an external circuit, allowing
Why large amplifiers draw so much current at switch-on
There are a couple of reasons why large linear power supplies, like those used
in high-power Class-A or Class-AB amplifiers, draw such a high current initially.
1. Charging the capacitor bank. When the reservoir capacitors are fully discharged, they initially present a very low impedance to the rectifier. The charging
current is limited mainly by the transformer winding resistance and leakage
inductance, rectifier and wiring resistance and the ESR of the capacitors. In a
large amplifier, the initial current can easily reach tens of amps.
2. Transformer magnetising inrush. Toroidal transformers, which are commonly used in high-power amplifiers, can draw an exceptionally large magnetising current when first energised. Transformer core flux depends on the integral
of the applied voltage, so switching on near a mains-voltage zero crossing can
produce a flux excursion much greater than occurs during normal operation.
Any remanent magnetisation left in the core can make this worse, potentially
driving the core into saturation. The resulting current can briefly reach hundreds of amps in a large transformer.
Switch-mode power supplies can also have high inrush currents. Small EMI
suppression capacitors connected across the mains can produce a very brief
current spike as they charge, although this is generally not the main source
of inrush.
More importantly, most mains-powered switch-mode supplies rectify the
mains to produce high-voltage DC, with a substantial electrolytic capacitor
connected to the DC bus. When the supply is first switched on, this capacitor
is discharged and can draw many tens of amps through the bridge rectifier
unless some form of inrush-current limiting or controlled pre-charge is provided.
the open-collector limit active output
to be used.
The delay required to reduce inrush
current is quite short. Usually, a handful of cycles is all that is required, so
a few hundred milliseconds. The recommended configuration implements
a one-second delay.
The delay is controlled by a single
resistor value, which is 10kW for the
default delay of one second. Changing
this to 2.2kW will make it more like
200ms, while increasing it will make
the delay much longer, up to 10 seconds with 100kW. However, if increasing the delay, you need to consider
the thermal limitations of the current-
limiting resistors, discussed later.
The open-collector output uses a
BC548 NPN transistor and can sink
up to 20mA reliably.
The maximum load current is
defined by the PCB; the PCB traces are
7mm wide, so they can safely handle
8A continuously. The relay itself is
rated at 16A; you have to derate that
for inductive loads like transformers, but since it’s switching when the
voltage across the 10W power resistors is already quite low, it isn’t being
worked hard.
Circuit description
Scope 1: the yellow trace is the unregulated DC supply voltage across the 470μF
capacitor, while the cyan trace is the negative end of the relay coil. The relay is
energised close to one second after power is applied.
46
Silicon Chip
Australia's electronics magazine
The circuit of the Inrush Current
Limiter is shown in Fig.1.
At power on, RLY1 is off, so mains
current and voltages comes in via the
ACTIVE IN terminal of CON2, through
the three 100W resistors in parallel,
then to the ACTIVE OUT terminal to
power the main toroidal transformer
and whatever else runs from mains
in the amplifier. Only the Active current flows through this board; Neutral
and Earth will be wired to the power
socket externally.
The Neutral connection on CON2
siliconchip.com.au
Fig.1: most of the circuit is involved in controlling RLY1 so that it switches on
one second after power is applied, shorting out the resistors that the Active
current otherwise has to flow through, between pins 1 & 2 of CON2. It’s also
designed to switch RLY1 off quickly after mains power is lost.
is to power this board, and there is
no Earth terminal, as the circuitry is
floating.
The Inrush Current Limiter circuit
is powered from the mains input via
a 3VA transformer, bridge rectifier and
470μF filter capacitor, producing a
roughly 17V unregulated DC supply.
That is dropped to a regulated 12V
DC by REG1, which powers the rest
of the circuit.
The rest of the circuit is essentially
a time delay so that NPN transistor
Q5 switches on roughly one second
after mains power is applied, energising RLY1 and shorting out the 100W
resistors. When that happens, mains
current to the appliance flows in via
ACTIVE IN, through the relay contact(s) and out through ACTIVE OUT,
bypassing the 100W resistors.
When mains power is switched off,
the circuit is designed to switch RLY1
off immediately so that the 100W resistors are back in-circuit in case power is
switched on immediately again.
Timer
Initially at power-on, the 100μF
capacitor will be discharged and thus
diode D7 will be reverse-biased. Q3’s
base is pulled up to +12V by the 100kW
resistor, so Q3 is off and so are Q5 and
Q6. The relay is not energised. The
100μF capacitor starts charging via
siliconchip.com.au
its series 10kW resistor (or whatever
value you’ve chosen).
The 100μF capacitor has to charge
to about 8.2V before anything happens. At that point, there’s enough
voltage to forward-bias diode D7 and
transistor Q3’s base-emitter junction.
This happens at 8.2V due to the voltage across 6.8V zener diode ZD1 plus
D7’s forward voltage (~0.7V) and Q3’s
base-emitter junction forward bias
voltage (~0.7V).
At that stage, Q3, Q5 and Q6 switch
on, the relay is energised and the
inrush current limiting resistors are
shorted out by the relay – see Scope 1.
Note that during this process, transistor Q1 is switched off and so it has
no effect on the charging of the 100μF
capacitor. We can verify this by looking
at the rest of the circuit. When there is
an AC output voltage from transformer
T1, periodically NPN transistor Q4
will switch on.
When it’s on, it discharges the 100nF
capacitor at its collector, so that capacitor can never charge sufficiently to
switch off PNP transistor Q2 due to the
time constant with the 100kW resistor
(100kW × 100nF = 10ms, but it needs
several time constants to charge sufficiently).
Thus, Q2 is switched on the whole
time that mains is applied to the circuit, and it pulls up the base of PNP
Australia's electronics magazine
transistor Q1, preventing it from
switching on.
About 75ms after mains power
is removed, with Q4 off, the 100nF
capacitor at the base of Q2 charges
to about 11.5V, switching Q2 off and
Q3 on and rapidly discharging the
100μF capacitor. Q3, Q5 & Q6 then all
immediately switch off and the relay
is de-energised, with D5 clamping its
back-EMF voltage spike.
Timing
The time constant for the 100μF
capacitor charging and thus the relay
switching is one second for R = 10kW
and C = 100μF.
Since this is linearly proportional to
R, all you really need to know is that
doubling the value of R doubles the
time delay, and halving it will halve
the time delay. Suitable values range
from about 2.2kW (<250ms) to 100kW
(5-10s).
Transformer options
For transformer T1, we’ve chosen a
small PCB-mounting 3VA transformer
from Altronics. Using this results in
minimal mains wiring, so the result
is neat and tidy. We’ve slotted the secondary holes so a standard 25mm-pitch
PCB-mounting transformer can be used
instead, such as Myrra’s 44199, available from element14.
December 2026 47
Parts List – Inrush Current Limiter
1 double-sided 110.5 × 88.5mm PCB coded 10110261
1 2-way polarised header, 2.54mm pitch (CON1; optional)
1 3-way 5/5.08mm mains-rated terminal block (CON2) [Altronics P2039]
1 PCB-mounting safety fuse holder (F1)
[Altronics S5987, Mouser 693-0031.3553]
1 200mA fast-blow M205 fuse (F1)
1 255VAC 16A SPST PCB-mount relay, 12V DC coil (RLY1)
[Altronics SA4198 or Hongfa HF14FW/012-HST(136)]
1 3VA 6+6V output mains transformer (T1) [Altronics M7012A, Myrra 44199]
1 micro-U TO-220 heatsink and mounting hardware (optional; see text)
[Altronics H0630]
1 100mm length of 1.6mm diameter heatshrink tubing
1 21 × 25mm piece of insulating material (eg, acrylic or Presspahn)
2 12mm nylon tapped spacers
4 M3 × 6mm plastic/nylon machine screws
M3 mounting hardware to suit application
Semiconductors
1 7812 12V 1A linear regulator, TO-220 (REG1)
3 BC558 30V 100mA PNP transistors, TO-92 (Q1-Q3)
3 BC548 30V 100mA NPN transistors, TO-92 (Q4-Q6)
1 6.8V 400mW/500mW axial zener diode, DO-35/DO-41 (ZD1)
4 1N4004 400V 1A power diodes, DO-41 (D1-D4)
5 1N4148 75V 150mA signal diodes, DO-35 (D5, D7-D10)
Capacitors
1 470μF 25V/35V electrolytic capacitor
1 100μF 25V electrolytic capacitor
3 100nF 50V/63V/100V ceramic or MKT capacitors
Resistors (all ¼W ±1% axial unless noted)
2 100kW
8 10kW (7 if using a timing resistor value other than 10kW)
3 100W 10W ±5% wirewound [Altronics R0435]
Fig.2: assembly is straightforward and all parts are through-hole types. Start
with the lower-profile components and work your way up to the taller ones,
watching the orientations of the diodes and transistors. Change the resistor
labelled in red for a different timeout (higher value = longer, lower = shorter).
48
Silicon Chip
Australia's electronics magazine
If you need to use a transformer
with flying leads, such as Altronics’
M2851A, we have included holes in
the PCB that allow you to use cable ties
to secure the wires to the PCB.
We are also using a PCB-mounting
safety fuse holder, with a 200mA fuse
for the 3VA transformer. There is room
for a small flag heatsink on the regulator, but this would only be required
if your transformer outputs more than
12V AC.
Construction
The Inrush Current Limiter is built
on a 110.5 × 88.5mm PCB that’s coded
10110261. Use the overlay diagram,
Fig.2, as a guide during construction.
Start by fitting all the small resistors. We are recommending a 10kW
timing resistor (value shown in red).
This gives a one-second soft start,
which worked well for our large test
amplifier. If you are not using the
open-collector output to disable your
speakers or load, a delay of 200ms (use
2.2kW) would be worth considering.
Follow by fitting the diodes. Do
not mix up the sole zener diode, the
small 1N4148 signal diodes and larger
1N4004 parts. Make sure the cathode
stripes all face as shown in Fig.2.
The three-way terminal block needs
to be mains-rated; Altronics Cat P2039
is suitably rated for this application.
Mount it now, plus CON1 if you will
be using it.
Now install all the transistors. There
are three each of the NPN (BC548)
and PNP (BC558) devices, so don’t
mix them up. Other transistors from
this series, like the BC547/BC557 and
BC549/BC559, could also be used.
Make sure the flat faces are orientated as shown. Follow these with
the voltage regulator, capacitors and
fuse holder.
The heatsink for REG1 isn’t required
if you’re using the recommended
transformer, but it wouldn’t hurt if
you fit it.
Finally, load the relay, the 10W
resistors and the transformer. Add
short lengths of heatshrink tubing to
these resistor leads before you solder
them so that once the board is running,
there is no possibility of you touching
these legs.
Testing
Connect a DC power supply set to
15V DC or more, with its negative output connected to the GND test point
siliconchip.com.au
Figs.3 & 4: a suggestion for how to wire the unit up. It’s pretty simple. We haven’t shown anything
connected to CON1 here; many applications won’t require it. Cut the shield shown here from a small piece
of insulating material like acrylic or Presspahn and attach it with plastic tapped spacers and plastic machine screws so
you can’t accidentally come in contact with the live screws on the top of terminal block CON2.
in the lower left of the board and the
positive to the “+UNREG” test point,
which is next to the 470μF capacitor.
Apply power and check the voltage
on the 12V test point in the top-right
corner of the board. This should be
12V ±0.5V. The relay will not click in
as there is no AC present.
If it doesn’t work:
• Is the 12V rail OK? If not, is the
DC input OK?
• If the output is low, is the regulator hot? If so, something is likely
shorted to ground.
• Is the 470μF capacitor the right
way around?
• Are the transistors and diodes in
the right way around?
Tack a piece of hookup wire to TP1,
which is just near the top left of the
transformer. With the DC power supply on, touch this to the +UNREG test
point. This should enable the AC presence detection system and the relay
should click in after about a second. If
this works, everything is good.
Once the board operates from the
DC supply as above, you are ready to
install it. Insert a 200mA M205 fuse
into the fuse holder. Wire the Inrush
Limiter into your circuit as shown in
Fig.3, ensuring that all the mains wiring is secured using cable ties.
Cut the shield shown in Fig.4 from
a sheet of Presspahn, acrylic or similar insulating material, drill two 3mm
siliconchip.com.au
holes as shown and mount it on nylon
tapped spacers using plastic/nylon
screws via the two holes in the PCB.
This covers the terminal block so you
can’t come into accidental contact
with the live screws on the top.
Apply power and check that the
relay clicks in after about a second.
If it does not, power it down, wait for
all capacitors to discharge and investigate.
Usage
quickly as we could, and repeating.
These twelve cycles took about 90
seconds. At the end, after discharging
and unplugging everything, the resistors were at about 50°C.
This is an unrealistic test, as if your
speakers are disabled at power off, the
main rails will not collapse in the few
seconds we took to discharge them
with a 4W resistor. So this suggests the
resistors will not live a stressful life
with normal usage. SC
We tested this with a 600VA
transformer loaded with
35,000μF capacitors on both
rails. Without the Inrush Limiter, the power board’s 20A
circuit breaker would kick
out with alarming regularity. With the Inrush Limiter in circuit, the start-up
was much more sedate; no
thumps from the transformer and everything was
controlled.
One concern is how
much dissipation occurs
in the 10W resistors.
We ran twelve cycles of
turning the circuit on,
then off, discharging
the main capacitors as
The assembled board.
The heatsink is optional.
Australia's electronics magazine
December 2026 49
|